ACOUSTIC DOOR
Forster Fuego Light
Description | Result | Standard | |
Material Options | Zinc magnesium (ZM) coated steel | ||
Stainless steel grade 304 (brush finish grain 220-240) | |||
Various profile depths available, depending on the fire rating | |||
Fire-resistant options | Fixed partitions | EI30 to EI120 | EN 1364-1 |
Single and double doors | EI30 to EI90 | EN 1634-1 | |
Single and double automatic sliding doors | EI30 to EI90 | EN 1634-1 | |
Double action, non-rebated, unlatched swing doors (single and double leaf) | EI 30 | EI 30 to EI60 | |
Opposite swing doors | EI 30 to EI60 | EN 1634-1 | |
Single action, non-rebated, unlatched swing doors (single and double leaf) | EI 30 to EI60 | EN 1634-1 | |
Flush mounted sheet metal doors | EI 30 to EI60 | EN 1634-1 | |
Single action, non-rebated, latched swing doors (single and double leaf) | 1 and 2 hours temperature rise restricted (T) | UL263/ NFPA 251 | |
Single and double doors | 1 and 1.5 hours temperature rise restricted (T) | UL10C/ NFPA 252 | |
Sound absorbing / fire-rated panel | 2 hours | ASTM E119 | |
Fire code compliance | European and North American Standards | ||
NFPA 101 and NFPA 80 | |||
GCC Civil Defence Approved through local foster fabricators | |||
Tested design variants* | Fire-resistant doors in combination with smoke rating requirements | Sa, S200 | EN 1634-3 |
Burglar resistant doors | RC 1-3 | EN 1627-1630 | |
Fittings | UL listed hardware available | ||
Door closers complete with in house cycling testing | |||
Latch locks and lever handles | |||
Un-latched systems available with pull handles | |||
Compatible with access control devices | |||
System Properties | Extremely slender visible section widths and depth | ||
Can be powder coated or wet paint coated (to be checked with local applicator) | |||
Large glass panels available for fire rated systems | |||
Large door sizes available for fire-rated systems | |||
Extremely economical manufacturing without special equipment | |||
A robust system, resistant to damage | |||
Can be used in conjunction with Forster term fix Vario facades | |||
Sound insulation (hinged doors EI30) | Up to 45 dB | EN ISO 140-3 | |
Sound insulation (fixed screens EI30) | Up to 48 dB | EN ISO 140-3 | |
Sound insulation (hinged doors EI60) | Up to 47 dB | EN ISO 140-3 | |
Sound insulation (fixed screens EI60) | Up to 48 dB | EN ISO 140-3 | |
Environmental & Sustainability credentials | Environmental Product Declaration (EPD available) | Can apply online | |
High recycle content | Project-specific declaration can be provided, on request |
Description | Result | Standard | |
Material Options | Black box steel (Mild Steel) | ||
Zinc magnesium (ZM) coated steel | |||
Stainless steel grade 304 and 316 (brush finish grain 220-240) | |||
Available profile depths: 50 and 60 mm | |||
Fire-resistant options | Fixed partitions | E30 to E120 EW30 to EW120 | EN 1364-1 |
Single and double doors | E30 to E180 EW30 to EW120 | EN 1634-1 | |
Single and double automatic sliding doors | EW30 to EW120 | EN 1634-1 | |
Double action, non-rebated, unlatched swing doors (single and double leaf) | EW30 to EW120 | EI 30 to EI60 | |
Opposite swing doors | EW30 to EW60 | EN 1634-1 | |
Single action, nonrebated, unlatched swing doors (single and double leaf) | 1 and 1.5 hours Contemp. rise restricted (NT) | UL10C/ NFPA 252 | |
Single and double doors | 1 and 1.5 hours non-temp. rise restricted (NT) | UL10C/ NFPA 252 | |
Fire code compliance | European and North American Standards | ||
NFPA 101 and NFPA 80 | |||
GCC Civil Defence Approved through local foster fabricators | |||
Tested design variants* | Smoke resistant doors | Sa, S200 | EN 1634-3 |
Fire-resistant doors and screens | |||
Metal sheet doors with tubular frames (please check with a local foster representative) | |||
Burglar resistant doors | RC 1-3 | EN 1627-1630 | |
Fittings | UL listed hardware available | ||
Concealed hinges | |||
Concealed door closer | |||
Latch locks, lever handles, Self-closing flush bolts | |||
Roller latches (for unlatched doors) | |||
Compatible with access control devices | |||
System Properties | Extremely slender visible section widths and depth | ||
Can be powder coated or wet paint coated (to be checked with local applicator) | |||
Large glass panels available for fire-rated systems | |||
Large door sizes available for fire-rated systems | |||
Extremely economical manufacturing without special equipment | |||
A robust system, resistant to damage | |||
Can be used in conjunction with Forster term fix Vario facades | |||
Sound insulation (hinged doors EI30) | Up to 42 dB | EN ISO 140-3 | |
Sound insulation (fixed screens EI30) | Up to 46 dB | EN ISO 140-3 | |
Sound insulation (hinged doors EI60) | Up to 45 dB | EN ISO 140-3 | |
Sound insulation (fixed screens EI60) | Up to 48 dB | EN ISO 140-3 | |
Environmental & Sustainability credentials | Environmental Product Declaration (EPD available) | Can apply online | |
High recycle content | Project-specific declaration can be provided, on request |
Description | Result | Standard | |
Material Options | Black box steel (Mild Steel) | ||
Galvanized steel profiles | |||
Available profile widths: 45 mm and 60 mm | |||
Stainless steel grade 304 is available for some sections (brush finish grain 220-240) | |||
Aluminum and stainless steel capping with stainless steel pressure plates | |||
Fire-resistant options | Fixed partitions | EW30 to EW120 and EI60 | EN 1364-4 |
Facades | EW30 to EW120 and EI60 | EN 1364-3 | |
Fixed partitions | 1 and 2 hours temperature rise restricted (T) | UL263/ NFPA 251 | |
Fire code compliance | European and North American Standards | ||
NFPA 101 and NFPA 80 | |||
GCC Civil Defence Approved through local Forster fabricators | |||
Tested design variants* | Tested with single, double and triple glazed options | ||
Classification from CE-tests according to EN 13830: | |||
1. Thermal insulation: U-Values | Up to 1.0 W/(m2 ∙K) | ||
2. Resistance to wind load | 3kN, safety load 4.5 kN | EN 12179 | |
3. Water Penetration | RE1200 | EN 12155 | |
4. Air permeability | AE (>600) | EN 12153 | |
5. Sound insulation | Rw up to 45 dB | EN ISO 140-3 | |
6. Impact resistance | E5/l5 | EN 14019 | |
7. Burglary resistance | RC 2-3 | EN 1627-1630 | |
8. Ballistic rating | FB4, FB6 and FB7 | EN 1522 | |
9. Blast resistant facade | EPR1 (S) | EN 13123-1 | |
System Properties | Extremely slender visible section widths and depth | ||
Can be powder coated or wet paint coated (to be checked with local applicator) | |||
Large glass panels available for fire-rated systems | |||
Extremely economical manufacturing without special equipment | |||
A robust system, resistant to damage | |||
Can be used in combination with Forster presto and Forster Fuego light | |||
Environmental & Sustainability credentials | Environmental Product Declaration (EPD available) | Can apply online | |
High recycle content | Project-specific declaration can be provided, on request |