ACOUSTIC DOOR
Forster Fuego Light
| Description | Result | Standard | |
| Material Options | Zinc magnesium (ZM) coated steel | ||
| Stainless steel grade 304 (brush finish grain 220-240) | |||
| Various profile depths available, depending on the fire rating | |||
| Fire-resistant options | Fixed partitions | EI30 to EI120 | EN 1364-1 |
| Single and double doors | EI30 to EI90 | EN 1634-1 | |
| Single and double automatic sliding doors | EI30 to EI90 | EN 1634-1 | |
| Double action, non-rebated, unlatched swing doors (single and double leaf) | EI 30 | EI 30 to EI60 | |
| Opposite swing doors | EI 30 to EI60 | EN 1634-1 | |
| Single action, non-rebated, unlatched swing doors (single and double leaf) | EI 30 to EI60 | EN 1634-1 | |
| Flush mounted sheet metal doors | EI 30 to EI60 | EN 1634-1 | |
| Single action, non-rebated, latched swing doors (single and double leaf) | 1 and 2 hours temperature rise restricted (T) | UL263/ NFPA 251 | |
| Single and double doors | 1 and 1.5 hours temperature rise restricted (T) | UL10C/ NFPA 252 | |
| Sound absorbing / fire-rated panel | 2 hours | ASTM E119 | |
| Fire code compliance | European and North American Standards | ||
| NFPA 101 and NFPA 80 | |||
| GCC Civil Defence Approved through local foster fabricators | |||
| Tested design variants* | Fire-resistant doors in combination with smoke rating requirements | Sa, S200 | EN 1634-3 |
| Burglar resistant doors | RC 1-3 | EN 1627-1630 | |
| Fittings | UL listed hardware available | ||
| Door closers complete with in house cycling testing | |||
| Latch locks and lever handles | |||
| Un-latched systems available with pull handles | |||
| Compatible with access control devices | |||
| System Properties | Extremely slender visible section widths and depth | ||
| Can be powder coated or wet paint coated (to be checked with local applicator) | |||
| Large glass panels available for fire rated systems | |||
| Large door sizes available for fire-rated systems | |||
| Extremely economical manufacturing without special equipment | |||
| A robust system, resistant to damage | |||
| Can be used in conjunction with Forster term fix Vario facades | |||
| Sound insulation (hinged doors EI30) | Up to 45 dB | EN ISO 140-3 | |
| Sound insulation (fixed screens EI30) | Up to 48 dB | EN ISO 140-3 | |
| Sound insulation (hinged doors EI60) | Up to 47 dB | EN ISO 140-3 | |
| Sound insulation (fixed screens EI60) | Up to 48 dB | EN ISO 140-3 | |
| Environmental & Sustainability credentials | Environmental Product Declaration (EPD available) | Can apply online | |
| High recycle content | Project-specific declaration can be provided, on request |
| Description | Result | Standard | |
| Material Options | Black box steel (Mild Steel) | ||
| Zinc magnesium (ZM) coated steel | |||
| Stainless steel grade 304 and 316 (brush finish grain 220-240) | |||
| Available profile depths: 50 and 60 mm | |||
| Fire-resistant options | Fixed partitions | E30 to E120 EW30 to EW120 | EN 1364-1 |
| Single and double doors | E30 to E180 EW30 to EW120 | EN 1634-1 | |
| Single and double automatic sliding doors | EW30 to EW120 | EN 1634-1 | |
| Double action, non-rebated, unlatched swing doors (single and double leaf) | EW30 to EW120 | EI 30 to EI60 | |
| Opposite swing doors | EW30 to EW60 | EN 1634-1 | |
| Single action, nonrebated, unlatched swing doors (single and double leaf) | 1 and 1.5 hours Contemp. rise restricted (NT) | UL10C/ NFPA 252 | |
| Single and double doors | 1 and 1.5 hours non-temp. rise restricted (NT) | UL10C/ NFPA 252 | |
| Fire code compliance | European and North American Standards | ||
| NFPA 101 and NFPA 80 | |||
| GCC Civil Defence Approved through local foster fabricators | |||
| Tested design variants* | Smoke resistant doors | Sa, S200 | EN 1634-3 |
| Fire-resistant doors and screens | |||
| Metal sheet doors with tubular frames (please check with a local foster representative) | |||
| Burglar resistant doors | RC 1-3 | EN 1627-1630 | |
| Fittings | UL listed hardware available | ||
| Concealed hinges | |||
| Concealed door closer | |||
| Latch locks, lever handles, Self-closing flush bolts | |||
| Roller latches (for unlatched doors) | |||
| Compatible with access control devices | |||
| System Properties | Extremely slender visible section widths and depth | ||
| Can be powder coated or wet paint coated (to be checked with local applicator) | |||
| Large glass panels available for fire-rated systems | |||
| Large door sizes available for fire-rated systems | |||
| Extremely economical manufacturing without special equipment | |||
| A robust system, resistant to damage | |||
| Can be used in conjunction with Forster term fix Vario facades | |||
| Sound insulation (hinged doors EI30) | Up to 42 dB | EN ISO 140-3 | |
| Sound insulation (fixed screens EI30) | Up to 46 dB | EN ISO 140-3 | |
| Sound insulation (hinged doors EI60) | Up to 45 dB | EN ISO 140-3 | |
| Sound insulation (fixed screens EI60) | Up to 48 dB | EN ISO 140-3 | |
| Environmental & Sustainability credentials | Environmental Product Declaration (EPD available) | Can apply online | |
| High recycle content | Project-specific declaration can be provided, on request |
| Description | Result | Standard | |
| Material Options | Black box steel (Mild Steel) | ||
| Galvanized steel profiles | |||
| Available profile widths: 45 mm and 60 mm | |||
| Stainless steel grade 304 is available for some sections (brush finish grain 220-240) | |||
| Aluminum and stainless steel capping with stainless steel pressure plates | |||
| Fire-resistant options | Fixed partitions | EW30 to EW120 and EI60 | EN 1364-4 |
| Facades | EW30 to EW120 and EI60 | EN 1364-3 | |
| Fixed partitions | 1 and 2 hours temperature rise restricted (T) | UL263/ NFPA 251 | |
| Fire code compliance | European and North American Standards | ||
| NFPA 101 and NFPA 80 | |||
| GCC Civil Defence Approved through local Forster fabricators | |||
| Tested design variants* | Tested with single, double and triple glazed options | ||
| Classification from CE-tests according to EN 13830: | |||
| 1. Thermal insulation: U-Values | Up to 1.0 W/(m2 ∙K) | ||
| 2. Resistance to wind load | 3kN, safety load 4.5 kN | EN 12179 | |
| 3. Water Penetration | RE1200 | EN 12155 | |
| 4. Air permeability | AE (>600) | EN 12153 | |
| 5. Sound insulation | Rw up to 45 dB | EN ISO 140-3 | |
| 6. Impact resistance | E5/l5 | EN 14019 | |
| 7. Burglary resistance | RC 2-3 | EN 1627-1630 | |
| 8. Ballistic rating | FB4, FB6 and FB7 | EN 1522 | |
| 9. Blast resistant facade | EPR1 (S) | EN 13123-1 | |
| System Properties | Extremely slender visible section widths and depth | ||
| Can be powder coated or wet paint coated (to be checked with local applicator) | |||
| Large glass panels available for fire-rated systems | |||
| Extremely economical manufacturing without special equipment | |||
| A robust system, resistant to damage | |||
| Can be used in combination with Forster presto and Forster Fuego light | |||
| Environmental & Sustainability credentials | Environmental Product Declaration (EPD available) | Can apply online | |
| High recycle content | Project-specific declaration can be provided, on request |